Refinery Cooling Water System Calibration 

  • Industry: Water & Utilities 
  • Region: US
  • Focus: Refinery utility system reliability & safety analysis 

Challenge

Hydrus Works, LLC needed to recalibrate a large refinery cooling water system containing nearly 600 pipes, 492 junctions, and 127 heat exchangers. Over 700 pressure, flow, and temperature measurements were taken, and the goal was to align the model with current system behavior for operational reliability. 

Solution

Hydrus used Fathom with extensive features including Scenario Manager, Global Editing, Goal Seek & Control, and custom Python tools to input metadata and calculate design and field K-factors. A calibration spreadsheet automated comparison of measured and modeled data, allowing iterative refinement. 

Results

Final calibrated model achieved flow matches within ±4.8% and pressure matches within ±1.8 psi. The model now serves as an evergreen asset enabling troubleshooting, planning, and system optimization. 

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.